- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources3
- Resource Type
-
0000000003000000
- More
- Availability
-
30
- Author / Contributor
- Filter by Author / Creator
-
-
Kemere, Caleb (3)
-
Adams, Jesse K. (1)
-
Boominathan, Vivek (1)
-
Carns, Jennifer (1)
-
Diba, Kamran (1)
-
Faghih, Rose T. (1)
-
Gale, John T. (1)
-
Gao, Sibo (1)
-
Han, Martin (1)
-
Hilliard, Justin D. (1)
-
Kim, Soonyoung (1)
-
McConnell, George C. (1)
-
Richards-Kortum, Rebecca (1)
-
Robinson, Jacob T. (1)
-
Rodriguez, Alex V. (1)
-
Santaniello, Sabato (1)
-
Veeraraghavan, Ashok (1)
-
Wu, Jimin (1)
-
Yan, Dong (1)
-
van der Meer, Matthijs A. (1)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract The simple and compact optics of lensless microscopes and the associated computational algorithms allow for large fields of view and the refocusing of the captured images. However, existing lensless techniques cannot accurately reconstruct the typical low-contrast images of optically dense biological tissue. Here we show that lensless imaging of tissue in vivo can be achieved via an optical phase mask designed to create a point spread function consisting of high-contrast contours with a broad spectrum of spatial frequencies. We built a prototype lensless microscope incorporating the ‘contour’ phase mask and used it to image calcium dynamics in the cortex of live mice (over a field of view of about 16 mm 2 ) and in freely moving Hydra vulgaris , as well as microvasculature in the oral mucosa of volunteers. The low cost, small form factor and computational refocusing capability of in vivo lensless microscopy may open it up to clinical uses, especially for imaging difficult-to-reach areas of the body.more » « less
-
Santaniello, Sabato; McConnell, George C.; Gale, John T.; Faghih, Rose T.; Kemere, Caleb; Hilliard, Justin D.; Han, Martin (, Frontiers in Neuroscience)
-
van der Meer, Matthijs A.; Kemere, Caleb; Diba, Kamran (, Philosophical Transactions of the Royal Society B: Biological Sciences)Patterns of neural activity that occur spontaneously during sharp-wave ripple (SWR) events in the hippocampus are thought to play an important role in memory formation, consolidation and retrieval. Typical studies examining the content of SWRs seek to determine whether the identity and/or temporal order of cell firing is different from chance. Such ‘first-order’ analyses are focused on a single time point and template (map), and have been used to show, for instance, the existence of preplay. The major methodological challenge in first-order analyses is the construction and interpretation of different chance distributions. By contrast, ‘second-order’ analyses involve a comparison of SWR content between different time points, and/or between different templates. Typical second-order questions include tests of experience-dependence (replay) that compare SWR content before and after experience, and comparisons or replay between different arms of a maze. Such questions entail additional methodological challenges that can lead to biases in results and associated interpretations. We provide an inventory of analysis challenges for second-order questions about SWR content, and suggest ways of preventing, identifying and addressing possible analysis biases. Given evolving interest in understanding SWR content in more complex experimental scenarios and across different time scales, we expect these issues to become increasingly pervasive. This article is part of the Theo Murphy meeting issue ‘Memory reactivation: replaying events past, present and future’.more » « less
An official website of the United States government
